- Novel System Design
- Efficient and economical design meeting the needs of the conventional HVAC market.
- Compact, low profile design to conform to typical architectural requirements.
- Easy access to all internal components through a large hinged access door and removable roof panel.
- Outdoor air inlet and exhaust air outlet located at opposite ends of unit for maximum separation.
- EXCLU-SIEVE Energy Recovery Wheel
- Certified total energy (both sensible and latent) recovery performance.
- Patented 3Å molecular sieve desiccant coating to avoid cross contamination.
- Easily removable wheel cassette module.
- Surpasses NFPA-90A requirements having a smoke and flame spread rating of 0 and 0, vs. 50 and 25 allowed by the standard.
- Self-adjusting air seals.
- Acid resistant face coating.
- Cabinet Construction
- Galvanized steel cabinet construction with enamel finish.
- Entire cabinet insulated to minimize energy loss.
- Hinged doors for easy access.
- Floor of the unit built as a pan to ensure watertight design.
- Supply and Exhaust Air Fans
- Sized for quiet and efficient operation.
- Mounted and balanced.
- Multiple motor/sheave selections for efficient adjustment of airflow.
- Filter Sections
- Filtration provided for both the outdoor air and return air.
- Hoods Dampers
- Supply airflow balancing dampers.
- Unit provided with an intake hood with a cleanable filter to limit rain and snow introduction.
- Exhaust air back draft damper on outside units only.
Electrical Package with Single Point Connection
- All motors wired to starters.
- Accepts contact inputs for supply fan start/stop, wheel start/stop and unit start/stop.
- Multiple options on input voltage to units:
- AQFlow Airflow Measuring System
- Simpler, more accurate system balancing in just five minutes.
- Easy measuring and adjusting of outdoor and exhaust air quantities.
- Accurate airflow ( /-6%) for the stand-alone FV unit or when mounted to a package rooftop unit where measuring outdoor air quantities is difficult.
- Reduced calls to engineers regarding air quantities.
- Peace of mind that proper ventilation is being provided to building occupants.
- Quick detection of problems like dirty filters, motor failure, power outage, etc.
- Meets intent of current ASHRAE standards for monitoring delivered fresh air quantities.
- Airflow quantities can be displayed on AQFlow.
- Electric Preheat (Optional)
- An electric preheat coil can be provided to avoid frosting conditions for installations in cold climates, which have high indoor humidity design conditions.
- Thermostat Frost Protection (Optional)
- Thermostatic frost control allows the entire FV unit to be turned off at a predetermined temperature when electric preheat is not desired.
- Control Package (Optional)
- Stop/Jog Economizer allows the wheel to be stopped automatically during mild outdoor temperatures with periodic brief rotation to maintain the self-cleaning feature of the heat exchanger.
- Wheel Frost Protection allows the wheel only to be stopped by the stop/jog economizer at a predetermined outdoor temperature in applications where a preheat coil or thermostat shut-off of the FV unit is not desired.
- Sensor can provide an alarm signal indicating failure of the wheel rotation.
- Remote Indicating Panel (Optional)
- SEMCO remote indicating panel provides a convenient and attractive option for monitoring the FV Preconditioner.
- Remote mounted Indicating panel provides status indicators for the following:
- Unit Power On
- Wheel Rotation Alarm
- Dirty Outside Air Filter
- Dirty Return Air Filter - Field wiring is only required from the remote panel to a low voltage terminal strip factory mounted on the FV unit. Remote indicating panel includes a junction box and plaster ring for recessed or surface mounting.
- Note: Control Package Option must also be selected for Wheel Rotation Alarm function.
- Dual Wall Construction (Optional)
- Interior of FV Preconditioner is lined with 22 gauge galvanized sheet metal.