There are over 15000 Fläkt Solyvent-Ventec fans operating in 30 nuclear plants worldwide.
Moreover we secure 75 reactors and waste treatment factories.
Handling of the manufacturing and development process matching your highest requirements:
TECHNICAL VALIDATION
- Mechanical, acoustic and aerodynamic calculations
- Seism calculation (Computational Aided Design for finite elements analysis and search for natural frequency)
- Tests on vibrating table
LEVELS OF SEALING
They are related to the environment stresses and made using various technologies (neutral gaz injection at the shaft, confined motor, enclosed motor)
INSPECTION OF WELDINGS
- Penetrant inspection at 20% and / or 100%
- X ray control of welding
COATINGS
Standard, decontaminating, acid proof
CONTROLS AND CERTIFICATES
- Welding operating process, qualified operator
- Control of tightness
- Material Certificates (document of compliance, acceptance certificate)
- List of operations of manufacturing and control
- Vibration, acoustic and aerodynamics tests
Location of our fans in a nuclear power plant
NUCLEAR PROCESS
Extracting fan for security
Standard conditions :
- Operates under 1 bar of absolute pressure
Specific designs and tests :
- Casing in cast iron and gastight
- Gastight electrical connections
- X rays tests of the welds and checking by ultra sound
Emergency conditions :
- Possibility to operate under 1,5 bar of absolute pressure
- Mixture of air and sodium – boric acid – hydrogen – radiation contamination
- Explosion resistant buiding
VENTILATION OF BATTERY ROOMS
Extracting fans for battery rooms (ATEX)
Battery rooms ventilation to secure installations which are sensitive to explosions (flammable vapors + electric equipments):
- Building complying to the ATEX 94/9/CE directive and EN NF14986 standard
- Specific coatings, acid proof
BUILDING VENTILATION ANNEXES
Vacuum fans for nuclear premises
- Dual ot three gang network for aerodynamic circuit
- Decontaminating coating according to the circuit
- Tightness according to the circuit
- Controlled weldings
MACHINE ROOM
Fans for building and ventilation vacuum
If an accident occurs, the machinery room must be under pressure
in order to avoid environmental pollution
OTHER USE
Cooling towers for oil cooler and building ventilation
- Oil cooling for transformers and lubrificating




Copyright 2011, Fläkt Woods Group. All rights reserved |